Part Number Hot Search : 
01032 4CBTLV3 CT431 HER307 826M0 ST19WG66 12NA60 MAX695
Product Description
Full Text Search
 

To Download CINT1175 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  CINT1175 175w single output industrial series www.slpower.com CINT1175 rev 5.4, 17-dec-12 1 features ? 2? x 4? x 1.3? package ? for 1u applications ? 175w w/air, 120w convection cooled ? universal input 90-264vac ? average efficiency meets level v requirements ? approved to csa/en/iec/ul60950, 2nd edition ? 12v fan output ? efficiency 90% typical at full load ? 3 year warranty ? rohs compliant description a highly dense 175watts ac to dc power supply designed for industrial and ite applications. with convection rating of 120 watts, CINT1175 family leads the market in power density and low leakage makes it a perfect solution for lighting applications. with input & output monitoring alarms plus isolated 12v/0.4a fan, it is one the most feature rich supplies and can easily fit in 1u chassis. all 5 models are ce marked to low voltage directive and approved to ite standards of en60950, 2nd edition. model selection model output current ripple & total ovp*** number volts w/200lfm air convection fan output noise** regulation threshold*** CINT1175a1206k01 12v 14.6a 11.7a 12vdc/0.4a 0.5%rms, 1.2% pk-pk ? 3% 14.0 ? 1.1v CINT1175a1506k01 15v 11.7a 9.3a 12vdc/0.4a 0.5%rms, 1.0% pk-pk ? 3% 18.5 1.5v CINT1175a2406k01 24v 7.3a 5.8a 12vdc/0.4a 0.5%rms, 1.2% pk-pk ? 3% 28.0 2.5v CINT1175a4806k01 48v 3.6a 2.9a 12vdc/0.4a 0.5%rms, 1.0% pk-pk ? 3% 55.0 4.0v CINT1175a5606k01 56v 3.1a 2.5a 12vdc/0.4a 0.5%rms, 1.0% pk-pk ? 3% 59.0 1.0v notes: * total convection power is 120 watts. * * m e a s u r e d w i t h n o i s e p r o b e d i r e c t l y a c r o s s o u t p u t t e r m i n a l s , a n d l o a d t e r m i n a t e d w i t h 0 . 1 f c e r a m i c a n d 1 0 f l o w e s r c a p a c i t o r s . *** output adjustment on 56v model will not exceed 56.2 volts. general specifications ac input 100-240vac, 10%, 47-63hz, 1 ? 120?370vdc turn on time less than 2 sec. @115vac (inversely proportional to input voltage and thermistor temperature) input current 115vac: 2a, 230vac: 1a hold-up time 16ms, typical inrush current 264vac, cold start: will not exceed 50a signals ac power fail, dc ok
CINT1175 175w single output industrial series www.slpower.com CINT1175 rev 5.4, 17-dec-12 2 general specifications (continued) input fuses f1, f2: 4a, 250vac fuses provided on all models overload protection hiccup mode earth leakage current < 7 5 0 a @ 2 6 4 v a c , 6 0 h z , n c short circuit protection provided - no damage will occur if the output is shorted. efficiency 90% typical at 115vac overvoltage protection ovp firing reduces output voltage to <50% of nominal in <50ms. see chart for trip range. output power 175w continuous, with 200 lfm airflow, 120w convection cooled ? see chart for specific voltage model ratings. switching frequency pfc: fixed, 65khz main converter: variable 35-200khz, 65- 70khz at full load. transient response 50% load step. ? i/ ? t : < 0 . 2 a / s max volt deviation = 3% isolation input-output: 4000vac input-ground: 1800vac output-ground: 1500vac ripple and noise see chart operating temperature -10c to +70c start up at -40c, full load output voltage see chart temperature derating derate output power linearly above 50c to 50% at 70c voltage adjustability +/- 5% from nominal storage temperature -40c to +85c minimum load not required altitude operating: -500 to 10,000 ft. non-operating: -500 to 40,000 ft. total regulation +/- 3%. see chart relative humidity 5% to 95%, non-condensing vibration operating: 0.003g/hz, 1.5grms overall, 3 axes, 10 min/axis non-operating: 0.026g2/hz, 5.0grms overall, 3 axes, 1 hr/axis shock operating: half-sine, 20gpk, 10ms, 3 axes, 6 shocks total non-operating: half-sine, 40 gpk, 10 ms, 3 axes, 6 shocks total dimensions w: 2.0? x l: 4.0? x h: 1.3? safety standards en/csa/ul/iec 60950-1, 2nd edition weight 210g mtbf 331,105 hours, 175w load, 110vac input, 25 c ambient auxiliary signals ac power fail: during normal operations, stays high. signal goes low with 5ms warning before loss of dc output from ac failure. dc ok: open collector logic signal goes and stays high 100ms to 500ms after main output reaches regulation. inhibit: connect to inhibit pin to output common to inhibit the dc output.
CINT1175 175w single output industrial series www.slpower.com CINT1175 rev 5.4, 17-dec-12 3 emi / emc compliance conducted emissions en55011/22 class b, fcc part 15, subpart b, class b radiated emissions en55011/22 class a, fcc part 15, subpart b, class a w/6db margin static discharge immunity en61000-4-2, criteria a, 6kv contact discharge, 8kv air discharge radiated rf immunity en61000-4-3, 3v/m. criteria a eft/burst immunity en61000-4-4, 2kv/5khz, criteria a line surge immunity en61000-4-5, 1kv differential, 2kv common-mode, criteria a conducted rf immunity en61000-4-6, 3vrms, criteria a power frequency magnetic field immunity en61000-4-8, 3a/m, criteria a voltage dip immunity en61000-4-11, 0% vin, 0.5cycle; 40% vin, 5 cycles; 70% vin, 25 cycles; criteria a line harmonic emissions en61000-3-2, class a, b, c, & d flicker test en61000-3-3, complies (dmax<6%) mechanical drawing
CINT1175 175w single output industrial series www.slpower.com CINT1175 rev 5.4, 17-dec-12 4 connector information input connector j100 ground j101 dc output connector j300 fan output connector j500 signal connector j600 pin 1) ac line pin 2) empty pin 3) ac neutral 0.25? faston tab pin 1) +vout pin 4) -vout pin 2) +vout pin 5) -vout pin 3) +vout pin 6) -vout pin 1) +12vfan pin 2) rtn pin 1) inhibit pin 2) pf/dc ok pin 3, 4) common mating connector: molex 09-50-3031 pins= 08-52-0072 mating connector: molex 01-90020009 mating connector: amp 640250-6 pins = 640252-1 mating connector: molex 1375820-2 pins = 1375819 mating connector: molex 1375820-4 pins = 1375819 fan output ? j500 j500 provides a 12v@0.4ma output to support a system cooling fan. the fan output is always available when ac input is present, so it also can be used for a 12v standby output is so desired. ac power failure/dc ok and inhibit signals ? j600 timing sequence
CINT1175 175w single output industrial series www.slpower.com CINT1175 rev 5.4, 17-dec-12 5 isolation specifications parameter conditions/description min nom max units insulation safety rating input/ground input/output output/ground basic reinforced n/a electric strength test voltage input/ground input/output output/ground 1800 4000 1500 - - vac vac vac input specifications all specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. parameter conditions/description min nom max units input voltage 90 115/230 264 vac turn-on input voltage ramping up 82.7 vac turn-off input voltage ramping down 67.0 vac input frequency 47 50/60 63 hz inrush current limitation 264vac, cold start - - 50 a power factor v i nom , i o nom 0.9 - - efficiency v i nom , i o nom CINT1175a1206k01 CINT1175a1506k01 CINT1175a2406k01 CINT1175a4806k01 CINT1175a5606k01 - 90% - % output specifications parameter conditions/description min nom max units output voltage setpoint accuracy CINT1175a1206k01 v i nom , , i o1 @ adc, t c = 25 c -3 - 3 % v o nom output voltage setpoint accuracy CINT1175a1506k01 v i nom , , i o1 @ adc, t c = 25 c -3 - 3 % v o nom output voltage setpoint accuracy CINT1175a2406k01 v i nom , , i o1 @ adc, t c = 25 c -3 - 3 % v o nom output voltage setpoint accuracy CINT1175a4806k01 v i nom , , i o1 @ adc, t c = 25 c -3 - 3 % vo nom output voltage setpoint accuracy CINT1175a5606k01 v i nom , , io1 @ adc, tc = 25 c -3 - 3 % vo nom output current v1 output current v2 CINT1175a1206k01 0 0 10.0 - 14.6 0.4 adc adc output current v1 output current v2 CINT1175a1506k01 0 0 8.0 - 11.7 0.4 adc adc output current v1 output current v2 CINT1175a2406k01 0 0 5.0 - 7.3 0.4 adc adc output current v1 output current v2 CINT1175a4806k01 0 0 2.5 - 3.6 0.4 adc adc output current v1 output current v2 CINT1175a5606k01 0 0 2.1 - 3.1 0.4 adc adc static line regulation v1 v i min- v i max, v i nom , 0-100% i o nom -1 - 1 % v o nom static load regulation v1 (droop characteristic) v i min- v i max, v i nom , 0-100% i o nom -3 - 3 % v o nom
CINT1175 175w single output industrial series www.slpower.com CINT1175 rev 5.4, 17-dec-12 6 output specifications (continued) parameter conditions/description min nom max units hold-up time starting at v i = 230 vac, p o nom - 16 - ms dynamic load regulation l o a d c h a n g e = 5 0 % , d i / d t = 0 . 2 a / s voltage deviation 3% 0 3 % v o nom start-up time v i nom , i o nom 0 - 2 s protection all specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted parameter conditions/description min nom max units input fuse not user accessible input transient protection 2kv(cm) and 1kv(dm) surge 2 kv (cm) output no-load and short circuit proof hiccup or latch short circuit proof hiccup or latch overload (latch style) hiccup overvoltage protection latch style latch over temperature protection automatic power shutdown at t c =155c characteristic curves output vs. temperature 120w convection cooled and 175w continuous with 200 lfm airflow, derating output power to 50% at 70 ? c.
CINT1175 175w single output industrial series www.slpower.com CINT1175 rev 5.4, 17-dec-12 7 efficiency vs. loading the high efficiency is achieved by using llc technology, pfc topology minimizing switching losses. synchronous schottky or ultra-fast diode is used as rectifier in CINT1175 family because of high output voltage level. noise & ripple to verify that the output ripple and noise does not exceed the level specified in the product specification. measured using a scope probe socket with 0.1uf ceramic and a 10uf electrolysis capacitor connected in parallel across it, bw limit with 20mhz.
CINT1175 175w single output industrial series www.slpower.com CINT1175 rev 5.4, 17-dec-12 8 output transient response 5 0 % l o a d s t e p w i t h i n t h e r e g u l a t i o n l i m i t s o f m i n i m u m a n d m a x i m u m l o a d , d i / d t < 0 . 2 a / s e c . r e c o v e r y t i m e n o t s p e c i f i e d a s t h e r e i s n o l a p s i n r e g u l a t i o n with a 50% load step. maximum voltage deviation is 3%, this test is performed on the main output only. output overload characteristic supply shall protect itself against overload conditions. the power supply shall recover from overload conditions without operator intervention. output overshoot when supply is turned on, off or when the load is stepped 100%, the power supply overshoot/undershoot shall not exceed minimum or maximum of output voltage regulation. data sheet ? 2012 sl power electronics corp. the information and specifications contained herein are believed to be correct at the time of publication. however, sl power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. specifications are subject to change without notice.


▲Up To Search▲   

 
Price & Availability of CINT1175

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .